4.19 Cogeneration of heat/cool and power from renewable non-fossil gaseous and liquid fuels (climate change mitigation)

Wirtschaftsaktivitäten (EU-Taxonomie) Europäische Union

Kurzbeschreibung

Construction and operation of combined heat/cool and power generation facilities using gaseous and liquid fuels of renewable origin. This activity does not include cogeneration of heat/cool and power from the exclusive use of biogas and bio-liquid fuels (see Section 4.20 of this Annex) The economic activities in this category could be associated with several NACE codes, in particular D35.11 and D35.30 in accordance with the statistical classification of economic activities established by Regulation (EC) No 1893/2006.

Wirtschaftsaktivität (EU-Taxonomie)

Rechtsakt: 2021/2139, Anhang I, Abschnitt 4.19 · ENERGY

Umweltziel: climate change mitigation

NACE-Codes: D35.11, D35.30

Beschreibung

Construction and operation of combined heat/cool and power generation facilities using gaseous and liquid fuels of renewable origin. This activity does not include cogeneration of heat/cool and power from the exclusive use of biogas and bio-liquid fuels (see Section 4.20 of this Annex) The economic activities in this category could be associated with several NACE codes, in particular D35.11 and D35.30 in accordance with the statistical classification of economic activities established by Regulation (EC) No 1893/2006.

Technische Bewertungskriterien

Technical screening criteria Substantial contribution to climate change mitigation 1. The life-cycle GHG emissions from the co-generation of heat/cool and power ( 192 ) from renewable gaseous and liquid fuels are lower than 100 g CO 2 e per 1 kWh of energy output from the co-generation. Life-cycle GHG emissions are calculated based on project-specific data, where available, using Recommendation 2013/179/EU or, alternatively, using ISO 14067:2018 ( 193 ) or ISO 14064-1:2018 ( 194 ). Quantified life-cycle GHG emissions are verified by an independent third party. 2. Where facilities incorporate any form of abatement (including carbon capture or use of decarbonised fuels) that abatement activity complies with the relevant Sections of this Annex, where applicable. Where the CO 2 that would otherwise be emitted from the cogeneration process is captured for the purpose of underground storage, the CO 2 is transported and stored underground, in accordance with the technical screening criteria set out in Sections 5.11 and 5.12 of this Annex. 3. The activity meets either of the following criteria: (a) at construction, measurement equipment for monitoring of physical emissions, such as methane leakage is installed or a leak detection and repair program is introduced; (b) at operation, physical measurement of methane emissions are reported and leak is eliminated. 4. Where the activity blends renewable gaseous or liquid fuels with biogas or bioliquids, the agricultural biomass used for the production of the biogas or bioliquids complies with the criteria laid down in Article 29, paragraphs 2 to 5, of Directive (EU) 2018/2001 while forest biomass complies with the criteria laid down in Article 29, paragraphs 6 and 7, of that Directive. Do no significant harm (‘DNSH’) (2) Climate change adaptation The activity complies with the criteria set out in Appendix A to this Annex. _____________ ( 192 ) Cogeneration is defined in Article 2 point 30 of Directive 2012/27/EU. ( 193 ) ISO standard 14067:2018, Greenhouse gases — Carbon footprint of products — Requirements and guidelines for quantification (version of 4.6.2021: https://www.iso.org/standard/71206.html). ( 194 ) ISO standard 14064-1:2018, Greenhouse gases — Part 1: Specification with guidance at the organization level for quantification and reporting of greenhouse gas emissions and removals (version of 4.6.2021: https://www.iso.org/standard/66453.html). (3) Sustainable use and protection of water and marine resources The activity complies with the criteria set out in Appendix B to this Annex. (4) Transition to a circular economy N/A (5) Pollution prevention and control Emissions are within or lower than the emission levels associated with the best available techniques (BAT-AEL) ranges set out in the latest relevant best available techniques (BAT) conclusions, including the best available techniques (BAT) conclusions for large combustion plants ( 195 ). No significant cross-media effects occur. For combustion plants with thermal input greater than 1 MW but below the thresholds for the BAT conclusions for large combustion plants to apply, emissions are below the emission limit values set out in Annex II, part 2, to Directive (EU) 2015/2193. (6) Protection and restoration of biodiversity and ecosystems The activity complies with the criteria set out in Appendix D to this Annex.

Diese Angaben wurden ohne KI deterministisch aus den Tabellen der genannten Quelldokumente geparst. Fehler bei der PDF-Auswertung sind dennoch möglich – im Zweifel gilt das Quelldokument.