7.3 Installation, maintenance and repair of energy efficiency equipment (climate change adaptation)

Wirtschaftsaktivitäten (EU-Taxonomie) Europäische Union

Kurzbeschreibung

Individual renovation measures consisting in installation, maintenance or repair of energy efficiency equipment. The economic activities in this category consist in one of the following individual measures, provided that they comply with minimum requirements set for individual components and systems in the applicable national measures implementing Directive 2010/31/EU and, where applicable, are rated in the highest two populated classes of energy efficiency in accordance with Regulation (EU) 2017/1369 and delegated acts adopted under that Regulation: (a) addition of insulation to existing envelope components, such as external walls (including green walls), roofs (including green roofs), lofts, basements and ground floors (including measures to ensure air-tightness, measures to reduce the effects of thermal bridges and scaffolding) and products for the application of the insulation to the building envelope (including mechanical fixings and adhesive); ___________ ( 588 ) EU Construction and Demolition Waste Protocol (version of 4.6.2021: https://ec.europa.eu/growth/content/eu-construction-and- demolition-waste-protocol-0_en). ( 589 ) ISO 20887:2020, Sustainability in buildings and civil engineering works - Design for disassembly and adaptability - Principles, requirements and guidance (version of 4.6.2021: https://www.iso.org/standard/69370.html). ( 590 ) Applying to paints and varnishes, ceiling tiles, floor coverings (including associated adhesives and sealants), internal insulation and interior surface treatments (such as to treat damp and mould). ( 591 ) ISO 16000-3:2011, Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method (version of 4.6.2021: https://www.iso.org/standard/51812.html). (b) replacement of existing windows with new energy efficient windows; (c) replacement of existing external doors with new energy efficient doors; (d) installation and replacement of energy efficient light sources; (e) installation, replacement, maintenance and repair of heating, ventilation and air-conditioning (HVAC) and water heating systems, including equipment related to district heating services, with highly efficient technologies; (f) installation of low water and energy using kitchen and sanitary water fittings which comply with technical specifications set out in Appendix A to Annex I to this Regulation and in case of shower solutions, mixer showers, shower outlets and taps have a max water flow of 6 L/min or less attested by an existing label in the Union market. The economic activities in this category could be associated with several NACE codes, in particular F42, F43, M71, C16, C17, C22, C23, C25, C27, C28, S95.21, S95.22, C33.12 in accordance with the statistical classification of economic activities established by Regulation (EC) No 1893/2006.

Wirtschaftsaktivität (EU-Taxonomie)

Rechtsakt: 2021/2139, Anhang II, Abschnitt 7.3 · CONSTRUCTION AND REAL ESTATE

Umweltziel: climate change adaptation

NACE-Codes: F42, F43, M71, C16, C17, C22, C23, C25, C27, C28, S95.21, S95.22, C33.12

Beschreibung

Individual renovation measures consisting in installation, maintenance or repair of energy efficiency equipment. The economic activities in this category consist in one of the following individual measures, provided that they comply with minimum requirements set for individual components and systems in the applicable national measures implementing Directive 2010/31/EU and, where applicable, are rated in the highest two populated classes of energy efficiency in accordance with Regulation (EU) 2017/1369 and delegated acts adopted under that Regulation: (a) addition of insulation to existing envelope components, such as external walls (including green walls), roofs (including green roofs), lofts, basements and ground floors (including measures to ensure air-tightness, measures to reduce the effects of thermal bridges and scaffolding) and products for the application of the insulation to the building envelope (including mechanical fixings and adhesive); ___________ ( 588 ) EU Construction and Demolition Waste Protocol (version of 4.6.2021: https://ec.europa.eu/growth/content/eu-construction-and- demolition-waste-protocol-0_en). ( 589 ) ISO 20887:2020, Sustainability in buildings and civil engineering works - Design for disassembly and adaptability - Principles, requirements and guidance (version of 4.6.2021: https://www.iso.org/standard/69370.html). ( 590 ) Applying to paints and varnishes, ceiling tiles, floor coverings (including associated adhesives and sealants), internal insulation and interior surface treatments (such as to treat damp and mould). ( 591 ) ISO 16000-3:2011, Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method (version of 4.6.2021: https://www.iso.org/standard/51812.html). (b) replacement of existing windows with new energy efficient windows; (c) replacement of existing external doors with new energy efficient doors; (d) installation and replacement of energy efficient light sources; (e) installation, replacement, maintenance and repair of heating, ventilation and air-conditioning (HVAC) and water heating systems, including equipment related to district heating services, with highly efficient technologies; (f) installation of low water and energy using kitchen and sanitary water fittings which comply with technical specifications set out in Appendix A to Annex I to this Regulation and in case of shower solutions, mixer showers, shower outlets and taps have a max water flow of 6 L/min or less attested by an existing label in the Union market. The economic activities in this category could be associated with several NACE codes, in particular F42, F43, M71, C16, C17, C22, C23, C25, C27, C28, S95.21, S95.22, C33.12 in accordance with the statistical classification of economic activities established by Regulation (EC) No 1893/2006.

Technische Bewertungskriterien

Technical screening criteria Substantial contribution to climate change adaptation 1. The economic activity has implemented physical and non-physical solutions (‘adaptation solutions’) that substantially reduce the most important physical climate risks that are material to that activity. 2. The physical climate risks that are material to the activity have been identified from those listed in Appendix A to this Annex by performing a robust climate risk and vulnerability assessment with the following steps: (a) screening of the activity to identify which physical climate risks from the list in Appendix A to this Annex may affect the performance of the economic activity during its expected lifetime; (b) where the activity is assessed to be at risk from one or more of the physical climate risks listed in Appendix A to this Annex, a climate risk and vulnerability assessment to assess the materiality of the physical climate risks on the economic activity; (c) an assessment of adaptation solutions that can reduce the identified physical climate risk. The climate risk and vulnerability assessment is proportionate to the scale of the activity and its expected lifespan, such that: (a) for activities with an expected lifespan of less than 10 years, the assessment is performed, at least by using climate projections at the smallest appropriate scale; (b) for all other activities, the assessment is performed using the highest available resolution, state-of-the-art climate projections across the existing range of future scenarios ( 592 ) consistent with the expected lifetime of the activity, including, at least, 10 to 30 year climate projections scenarios for major investments. 3. The climate projections and assessment of impacts are based on best practice and available guidance and take into account the state-of-the-art science for vulnerability and risk analysis and related methodologies in line with the most recent Intergovernmental Panel on Climate Change reports ( 593 ), scientific peer-reviewed publications and open source ( 594 ) or paying models. _____________ ( 592 ) Future scenarios include Intergovernmental Panel on Climate Change representative concentration pathways RCP2.6, RCP4.5, RCP6.0 and RCP8.5. ( 593 ) Assessments Reports on Climate Change: Impacts, Adaptation and Vulnerability, published periodically by the Intergovernmental Panel on Climate Change (IPCC), the United Nations body for assessing the science related to climate change produces, https://www.ipcc.ch/reports/. ( 594 ) Such as Copernicus services managed by the European Commission. 4. The adaptation solutions implemented: (a) do not adversely affect the adaptation efforts or the level of resilience to physical climate risks of other people, of nature, of cultural heritage, of assets and of other economic activities; (b) favour nature-based solutions ( 595 ) or rely on blue or green infrastructure ( 596 ) to the extent possible; (c) are consistent with local, sectoral, regional or national adaptation plans and strategies; (d) are monitored and measured against pre-defined indicators and remedial action is considered where those indicators are not met; (e) where the solution implemented is physical and consists in an activity for which technical screening criteria have been specified in this Annex, the solution complies with the do no significant harm technical screening criteria for that activity. Do no significant harm (‘DNSH’) (2) Climate change mitigation The building is not dedicated to extraction, storage, transport or manu­ facture of fossil fuels. (3) Sustainable use and protection of water and marine resources N/A (4) Transition to a circular economy N/A (5) Pollution prevention and control Building components and materials comply with the criteria set out in Appendix C to this Annex. In case of addition of thermal insulation to an existing building envelope, a building survey is carried out in accordance with national law by a competent specialist with training in asbestos surveying. Any stripping of lagging that contains or is likely to contain asbestos, breaking or mech­ anical drilling or screwing or removal of insulation board, tiles and other asbestos containing materials is carried out by appropriately trained personnel, with health monitoring before, during and after the works, in accordance with national law. (6) Protection and restoration of biodiversity and ecosystems N/A

Diese Angaben wurden ohne KI deterministisch aus den Tabellen der genannten Quelldokumente geparst. Fehler bei der PDF-Auswertung sind dennoch möglich – im Zweifel gilt das Quelldokument.